
Clinics and hospitals
From 5-minute motion analysis to digital therapeutic, on one system
4DEYE Dx, an MFDS Class II medical device, finds joint path deviations and compensation in five minutes. 4DEYE DTx, with its confirmatory trial completed, continues rehabilitation at home. You subscribe instead of buying, and hospitals recovered it within 3 weeks to 3 months.
- Upfront cost
- Zero · subscription
- Payback period
- 3 weeks – 3 months (measured)
- Evidence
- 6 SCI papers · confirmatory trial completed
- Approval · billing code
- MFDS Class II · EZ774
Dx + DTx
Dx runs the assessment. DTx takes it from there.
One flow, not two products. The assessment pinpoints compensation and joint dysfunction, and targeted exercise is prescribed. Patients continue on the same data after discharge, so the hospital can add rehab management revenue to assessment revenue.
- 4DEYE Dx
5-minute motion analysis
- 4DEYE Dx
Compensation and function analysis
- 4DEYE Dx
Report · PACS · claims
- 4DEYE DTx
Digital therapeutic prescription
- 4DEYE DTx
Exercise scoring · re-assessment
Monitoring results set the baseline for the next 4DEYE Dx assessment, closing the loop.
4DEYE Dx — finds the problem
Five minutes in clinic to find where the joint leaves its path, recorded in a report.
4DEYE DTx — carries it on
The clinician prescribes exercise for the problems found. A home camera scores each session, and results return to the clinician’s dashboard.
Rehabilitation medicine · physiotherapy
We put numbers on what you already see
You already assess compensation by eye and hand, and you are usually right. But those findings go undocumented, vary between therapists and are not tracked over time.
- 01
One simple movement is enough
A single simple movement, like raising the arm forward, automatically shows where the joint leaves its path.
- 02
The report is written for you
Results fit on one page and link directly to PACS and insurance claims, cutting paperwork for physiotherapists.
- 03
You see what was done at home
A home camera scores prescribed exercises, and adherence and pain changes flow into your dashboard.

Orthopedics
Before and after procedures, on one yardstick
Surgery and injections reduce pain, but whether the joint moves properly again is a separate question. If compensation remains, the problem returns.
- 01
Function and pain, seen separately
A lower VAS does not mean function has returned. Range of motion, alignment, left–right difference and compensation are each measured.
- 02
The pre-operative state stays on record
A five-minute pre-op assessment sets the baseline for the whole recovery.
- 03
No extra consultation time
The physician orders it, the physiotherapist runs it, and you read the report.

4DEYE DTx
Rehab usually ends at discharge
No one knows what exercise was done, and the next visit brings only “a bit better.” 4DEYE DTx fills that gap with data. Unlike exercise apps, its effect was shown in a confirmatory trial.

The prescription travels
Pick exercises to match the results, set sets, reps and frequency, and the plan goes to the patient’s phone. No paper handouts.

A camera scores the motion
At home, the camera scores posture accuracy and corrects errors on the spot.

You see who slipped
Adherence and pain (NRS) trends on one screen. AI flags drop-offs; send a reminder by KakaoTalk or text.
Evidence on our own product
Accuracy first, then effect — proven in order
Five papers show accurate, repeatable measurement against VICON, from single joints to whole-body movement. The sixth shows exercise content built on it corrects posture.
Same motion, VICON vs. 4DEYE: how close are the values?
ICC near 1.00 means values match VICON. ≥ 0.75 is "good"; ≥ 0.90 is "excellent".
Poor0.5
Moderate0.75
Good0.9
Excellent
Concurrent validity
ICC 0.75–0.99
Hip, knee and trunk measured together · Applied Sciences 2024
Angle-trajectory validity
ICC 0.86–1.00
Sitting, standing and squats · Journal of Human Kinetics 2023
Test–retest reliability
ICC 0.68–0.99
Same motion, same value on retest · Sensors 2023 · JHK 2023
ICC near 1.00 means close agreement with VICON — not that a treatment works. We keep the two claims separate.
How each one measures
VICON
- Reflective markers on every joint
- Infrared cameras in a dedicated lab
- 20–30 min setup
4DEYE
- Nothing attached to the body
- Five RGB cameras, existing rehab room
- 5-minute test

Beyond measurement — effect, too
In a cluster RCT of 36 adolescents (Medicine, IF 1.4), digital exercise content alone improved posture about as much as in-person therapist coaching.
Knee pain confirmatory trial, on our product
Prof. Lee Byung-hoon’s team, Orthopaedic Surgery, Gachon University Gil Medical Center · Single-centre · assessor-blinded · parallel-group · ITT · n=151 (78 vs 73) · 12 weeks

Primary endpoint · KOOS-12 function score
+5.24P < .001
Secondary outcomes improved too
- Quality of life (SF-12 physical) +7.35 · mental +5.83
- Knee flexion ROM +3.08°
- Adherence 81.4% (control 77.2%)
IRB GCIRB2025-212 · CRIS KCT0011905






Six SCI(E) papers, in Sensors, Applied Sciences, Journal of Human Kinetics, Medicine and more.
Clinical and public partners
Research in hospitals, results in the field
University hospital teams and an open lab validate performance and safety; a public education programme tests it in the field.


Prof. Lee Sang-heon’s team, Rehabilitation Medicine, Korea University Anam Hospital
Clinical site 1 · PI, non-specific low back pain DTx trial under way
Photo: Korea University Medicine PR Manager, CC BY-SA 4.0, Wikimedia Commons


Prof. Lee Byung-hoon’s team, Orthopaedic Surgery, Gachon University Gil Medical Center
Clinical site 2 · PI, chronic knee pain DTx trial completed


Open Lab, Korea University Guro Hospital
Research lab · R&D and clinical advice
Photo: Korea University Medicine PR Manager, CC BY-SA 4.0, Wikimedia Commons


Gyeonggi Provincial Office of Education
2024–present · student postural imbalance programme
Photo: SYM Healthcare · student postural imbalance prevention class
Real payback periods
Payback in three weeks to three months
Not projections: based on actual assessment volumes. Hospital names are initials per contract.
Bundang Hospital B passes 1,500 assessments a month
At a single hospital, in one month.
- Bundang Hospital B
- Ansan Hospital O
- Seoul Hospital C
Bundang Hospital B
266% in three weeks
266% of the purchase price recovered in three weeks, from 1,278 assessments. Monthly volume passed 1,500 as of Sep 2026.
- Payback
- 266%
- Time to payback
- 3 weeks
Ansan Hospital O
193% in two months
Payback rose from 62% to 193% in two months; monthly volume from 182 to 422 (Sep 2026).
- Payback
- 193%
- Time to payback
- 2 months
Seoul Hospital C
100% in three months
Full purchase price recovered in three months. Monthly volume reached 312 as of Sep 2026.
- Payback
- 100%
- Time to payback
- 3 months
No upfront cost. Profit from the first patient.
- Upfront cost
- KRW 0. Subscription, no equipment to buy
- Billing
- Per assessment; rate drops as volume grows
- Term
- 36 months, monthly minimum
- Break-even
- No upfront spend. Profit from the first patient
Rates and monthly minimums depend on hospital size and joints in use. We cover them in a consultation.
Hospital management
Know when it pays back, in numbers
Every assessment is logged automatically, so you track operations in real figures, not guesses.
- 01
The assessment leads to further care
Findings lead to physiotherapy, then orthopedic consultation and procedures. Post-surgical recovery management becomes billable too.
- 02
Claims backed by numbers
Measured values, not impressions, make the test’s need and results easy to explain.

Billing
The billing basis is already in place
4DEYE Dx is an MFDS Class II medical device. Motion analysis (biomechanical testing) is billable under non-covered service code EZ774. GMP and ISO 13485 certified.
Each institution sets and posts its own non-covered fees. We do not set them; we help your staff fit the test set-up and code to your clinical protocol.
Features by use
Clinical motion analysis is different, feature by feature
The wellness edition for sports, schools, industry and senior care involves no medical judgement: it offers posture and posture type data, growth prediction, a personalized exercise app, and injury-risk screening in sports. Joint-by-joint motion analysis, clinical use and claims, and digital therapeutic prescription are clinical edition only.
| Feature | Clinical edition 4DEYE Dx (MFDS-approved medical device) / DTx Clinics and hospitals · rehab medicine · orthopedics · physiotherapy | Wellness edition For sports, schools, industry and seniors · non-medical Athletes · students · workers · older adults |
|---|---|---|
| Motion analysis · clinical use | ||
Single- and multi-joint motion analysis Range of motion · compensation · left–right asymmetry | Included | Not included |
Movement screening Injury-risk screens such as Y-balance and overhead squat · sports only | Included | Included |
Tight and weak muscles · risk grade Findings that support clinical judgement | Included | Not included |
Hand function test Detailed finger, wrist and elbow analysis · separate attachment | Separate subscription | Not included |
Report linked to PACS and claims Connected to medical records and billing | Included | Not included |
| Treatment · follow-through | ||
Digital therapeutic prescription Clinician-prescribed · camera scoring · confirmatory trial evidence | Included | Not included |
Personalized exercise app Exercise matched to results · adherence tracking | Included | Included |
| Posture | ||
Current posture measurement 3 seconds · coronal, sagittal and transverse alignment | Included | Included |
Posture type classification Forward head · rounded shoulders · pelvic tilt and more | Included | Included |
Measurement data · trends Individual and group records on one yardstick | Included | Included |
| Growth · vital signs | ||
Growth prediction model Growth trends for students · in use in schools | Included | Included |
Heart rate · respiratory rate Contactless, via remote photoplethysmography (rPPG) from camera video | Coming soon | Coming soon |
Heart rate variability (HRV) · stress index Based on LF/HF and SDNN | Coming soon | Coming soon |
Blood pressure · oxygen saturation Collected during the same session | Coming soon | Coming soon |
Clinical edition
4DEYE Dx (MFDS-approved medical device) / DTx
Wellness edition
For sports, schools, industry and seniors · non-medical
Motion analysis · clinical use
Single- and multi-joint motion analysis
Range of motion · compensation · left–right asymmetry
IncludedNot includedMovement screening
Injury-risk screens such as Y-balance and overhead squat · sports only
IncludedIncludedTight and weak muscles · risk grade
Findings that support clinical judgement
IncludedNot includedHand function test
Detailed finger, wrist and elbow analysis · separate attachment
Separate subscriptionNot includedReport linked to PACS and claims
Connected to medical records and billing
IncludedNot included
Treatment · follow-through
Digital therapeutic prescription
Clinician-prescribed · camera scoring · confirmatory trial evidence
IncludedNot includedPersonalized exercise app
Exercise matched to results · adherence tracking
IncludedIncluded
Posture
Current posture measurement
3 seconds · coronal, sagittal and transverse alignment
IncludedIncludedPosture type classification
Forward head · rounded shoulders · pelvic tilt and more
IncludedIncludedMeasurement data · trends
Individual and group records on one yardstick
IncludedIncluded
Growth · vital signs
Growth prediction model
Growth trends for students · in use in schools
IncludedIncludedHeart rate · respiratory rate
Contactless, via remote photoplethysmography (rPPG) from camera video
Coming soonComing soonHeart rate variability (HRV) · stress index
Based on LF/HF and SDNN
Coming soonComing soonBlood pressure · oxygen saturation
Collected during the same session
Coming soonComing soon
Contactless vital signs are developed and launching soon; the wellness edition shows them as reference indicators without medical judgement. Hand function testing needs a separate attachment and subscription.
The consultation includes a live assessment and a payback simulation based on your hospital’s size and the joints you plan to assess.
Show patients the movement they can’t see
See a live assessment, terms sized to your hospital, and a payback simulation.
